dc.description.abstractThree mixtures were made for conventional concrete with different additions of cement, 300 kg/m3, 350 kg/m3 and 400 kg/m3, being these the 3 designs of mixtures more used for the elaboration of simple concretes. For each of the conventional mixtures, the % of water used for mixing was varied, which constituted 60%, 65% and 70% of the weight of the cementitious material. These % were taken in gradual increase to the one traditionally used in each of the mixing designs made. The aggregates used were assigned by Transmateriales S.A, located in the city of San José de Cúcuta, Colombia. The analysis of the materials of the mixtures, were carried out under the standards of the "Normas Tecnicas Colombianas" and the Tests of the "Instituto Nacional de Vías". 40% of the concrete mix cementitious material was replaced by fly ash and hydrated lime. In order to determine the mechanical behavior of the mixtures resulting from partial addiction. The ash was collected from the thermoelectric Termotasajero S.A, located in the city of San José de Cúcuta, Colombia. The hydrated lime was recovered from the municipality of Malaga located in the department of Santander, Colombia. Of the % of cementitious material replaced, 30% corresponded to lime and 70% to ash, as an experimental basis for the production of unconventional mixtures. Having the % of cementitious material to replace and the % of substitute material, 3 designs of experimental mixtures were made taking as base each one of the designs of conventional mixtures made, with equal % of water for its mixing. Twenty-seven cylinders were manufactured for the experimental mixtures and the same number for conventional mixtures, a figure that corresponded to the production of 3 specimens per % of water added in each of the established mixture designs. The compressive strength of the cylinders made in the materials resistance laboratory of the Universidad Francisco de Paula Santander, San José de Cúcuta, Colombia was tested. It was concluded in the influence of the % of water in the mechanical resistance of the experimental mixtures and the viability of the use of this type of mixtures in the elaboration of nonstructural concretes, data of importance with which the construction costs would be reduced considerably, generating in turn, a positive environmental impact by means of the inclusion of residual materials in the concrete mixtures.eng
dc.format.extent07 páginasspa
dc.format.mimetypeapplication/pdfspa
dc.language.isoengspa
dc.publisherJournal of Physics: Conference Seriesspa
dc.relation.ispartofJournal of Physics: Conference Series
dc.rights© Copyright 2021 IOP Publishingeng
dc.sourcehttps://iopscience.iop.org/article/10.1088/1742-6596/1386/1/012085/metaspa
dc.titleInfluence of water/cement ratio on mechanical strength of concrete with partial addition of fly ash and hydrated limeeng
dc.typeArtículo de revistaspa
dcterms.referencesPatiño-Murillo J A, Gutierrez-Sandoval Y C, Leal-Santafe J I, Castro-Maldonado J J and Hurtado-Figueroa O 2018 Lámpsakos 20 22spa
dcterms.referencesGholampour A and Ozbakkaloglu T 2018 Eng. Struct. 157 234spa
dcterms.referencesGarcía-Leon R, Flórez-Solano E and Acevedo-Peñaloza C 2018 Rev. Colomb. Tecnol. Av. 1 31spa
dcterms.referencesLee J H, Kang S H, Ha Y J and Hong S G 2018 Int. J. Concr. Struct. Mater. 12 1spa
dcterms.referencesHurtado-Figueroa O, Cardenas-Gutierrez J A and Rojas-Suarez J P 2018 J. Phys. Conf. Ser. 1126 012041spa
dcterms.referencesHurtado-Figueroa O, Cardenas-Gutierrez J A and Prada-Botia G 2018 J. Phys. Conf. Ser. 1126 012037spa
dcterms.referencesCastro Maldonado J, Dulcé Moreno H and Aperador W 2016 J. Phys. Conf. Ser. 687 012004spa
dcterms.referencesMohammadinia A, Wong Y, Arulrajah A and Horpibulsuk S 2019 Constr. Build. Mater. 197 496spa
dcterms.referencesFerrer M, Peña G and Dulce H 2011 Revista Colombiana de Física 43 2spa
dcterms.referencesGelves Díaz J F, Sánchez Molina J and Peña Rodríguez G 2009 Respuestas 14 2spa
dcterms.referencesHurtado-Figueroa O, Cardenas-Gutierrez J A and Gallardo O 2018 J. Phys. Conf. Ser. 1126 012040spa
dcterms.referencesHurtado-Figueroa O, Cardenas-Gutierrez J A and Acevedo-Peñaloza C 2018 Contemporary Engineering Sciences 11 4995spa
dcterms.referencesHurtado-Figueroa O, Cordero-Estevez G and Cardenas-Gutierrez 2018 Contemporary Engineering Sciences 11 100spa
dcterms.referencesBarrientos Monsalve E J, Franco Carreno M C, Buelvas Gutiérrez E D, Morris Molina L H, Franco Garcia J C and Bautista Rangel H M 2019 J. Phys. Conf. Ser. 1160 012011spa
dcterms.referencesYazdi M A, Yang J, Yihui L and Su H 2015 International Journal of Civil and Environmental Engineering 9 12spa
dcterms.referencesInstituto Colombiano de Normas Tecnicas y Certificacion (ICONTEC) 1982 Ingeniería civil y arquitectura. Cemento Pórtland. Especificaciones físicas y mecánicas, NTC121 (Colombia: Instituto Colombiano de Normas Tecnicas y Certificacion)spa
dcterms.referencesInstituto Colombiano de Normas Tecnicas y Certificacion (ICONTEC) 1982 Ingeniería civil y arquitectura. Cemento pórtland. Especificaciones químicas, NTC321 (Colombia: Instituto Colombiano de Normas Tecnicas y Certificacion)spa
dcterms.referencesInstituto Colombiano de Normas Tecnicas y Certificacion (ICONTEC) 1966 Cemento pórtland. Clasificación y nomenclatura, NTC30 (Colombia: Instituto Colombiano de Normas Tecnicas y Certificacion)spa
dcterms.referencesInstituto Colombiano de Normas Tecnicas y Certificacion (ICONTEC) 2007 Concretos. Método de ensayo para el analisis por tamizado de los agregados finos y gruesos, NTC77 (Colombia: Instituto Colombiano de Normas Tecnicas y Certificacion)spa
dcterms.referencesInstituto Colombiano de Normas Tecnicas y Certificacion (ICONTEC) 1995 Ingeniería civil y arquitectura. Determinación de la masa unitaria y los vacíos entre partículas de agregados, NTC92 (Colombia: Instituto Colombiano de Normas Tecnicas y Certificacion)spa
dcterms.referencesEnsayos del Instituto Nacional de Vias (INV E) 2007 Indice de aplanamiento y de alargamientode los agregados para carreteras, INV E230 (Colombia: Instituto Nacional de Vias)spa
dcterms.referencesInstituto Colombiano de Normas Tecnicas y Certificacion (ICONTEC) 1995 Ingeniería civil y arquitectura. Método para determinar la densidad y la absorción del agregado fino, NTC237 (Colombia: Instituto Colombiano de Normas Tecnicas y Certificacion)spa
dcterms.referencesInstituto Colombiano de Normas Tecnicas y Certificacion (ICONTEC) 1995 Ingeniería civil y arquitectura. Método de ensayo para determinar ladensidad y la absorción del agregado grueso, NTC176 (Colombia: Instituto Colombiano de Normas Tecnicas y Certificacion)spa
dcterms.referencesInstituto Colombiano de Normas Tecnicas y Certificacion (ICONTEC) 1995 Ingeniería civil y arquitectura. Determinación de la resistencia al desgaste de agregados gruesos hasta de 37,5 mm, utilizando la máquina de los ángeles, NTC98 (Colombia: Instituto Colombiano de Normas Tecnicas y Certificacion)spa
dcterms.referencesInstituto Colombiano de Normas Tecnicas y Certificacion (ICONTEC) 2004 Cal hidratada para mampostería, NTC4019 (Colombia: Instituto Colombiano de Normas Tecnicas y Certificacion)spa
dcterms.referencesInstituto Colombiano de Normas Tecnicas y Certificacion (ICONTEC) 1995 Concretos. Agua para la elaboración de concreto, NTC3459 (Colombia: Instituto Colombiano de Normas Tecnicas y Certificacion)spa
dcterms.referencesInstituto Colombiano de Normas Tecnicas y Certificacion (ICONTEC) 2010 Concretos. Ensayo de resistencia a la compresion de especimenes cilindricos de concreto, NTC673 (Colombia: Instituto Colombiano de Normas Tecnicas y Certificacion)spa
dc.identifier.doihttps://doi.org/10.1088/1742-6596/1386/1/012085
dc.publisher.placeReino Unidospa
dc.relation.citationeditionVol.1386 No.1.(2019)spa
dc.relation.citationendpage7spa
dc.relation.citationissue1(2019)spa
dc.relation.citationstartpage1spa
dc.relation.citationvolume1386spa
dc.relation.citesHurtado-Figueroa, O., Echavarria-Paez, F. J., & Cárdenas-Gutiérrez, J. A. (2019, November). Influence of water/cement ratio on mechanical strength of concrete with partial addition of fly ash and hydrated lime. In Journal of Physics: Conference Series (Vol. 1386, No. 1, p. 012085). IOP Publishing.
dc.relation.ispartofjournalJournal of Physics: Conference Seriesspa
dc.rights.accessrightsinfo:eu-repo/semantics/openAccessspa
dc.rights.creativecommonsAtribución 4.0 Internacional (CC BY 4.0)spa
dc.type.coarhttp://purl.org/coar/resource_type/c_6501spa
dc.type.contentTextspa
dc.type.driverinfo:eu-repo/semantics/articlespa
dc.type.redcolhttp://purl.org/redcol/resource_type/ARTspa
oaire.accessrightshttp://purl.org/coar/access_right/c_abf2spa
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85spa
dc.type.versioninfo:eu-repo/semantics/publishedVersionspa


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem