dc.description.abstractAn experimental investigation was made in search of the improvement of the material used for the conformation of the subgrade in pavements. Three separate excavations were carried out 150 m apart in a 510 m stretch located in the Guayabal environmental technology park in the city of San José de Cúcuta, Colombia. In each excavation 2 samples were taken at depths of 0.50 m and 1 m. The soil samples extracted were analyzed in accordance with the regulations of the "Instituto Nacional de Vías" of Colombia in its update of 2013. It was collected material, not superior to 20 mm, of biosanitary residues treated by the Ecosterile machine series 250C located in the environmental technological park Guayabal. Five experimental mixtures were carried out partially substituting 2%, 6%, 8%, 10% and 14% of the weight of the excavated soil with treated biosanitary residues, random percentages taken as initial reference in the experimentation due to the characteristics of the substitute material. The California bearing ratio test was performed on experimental mixtures whose data were tabulated and compared with those obtained in similar tests carried out on the material conventionally used for the improvement of the subgrade in pavements according to Colombian regulations. The tests provided interesting information that concluded in the substitution of 2% of the conventional material to improve the performance of the subgrade in the intervened section, a value that obtained better results in the California bearing ratio test, yielding 79.2% with respect to the result obtained by the conventional material. The exposed results are convenient for the economy of road projects due to the partial substitution of traditional material by residual material, at the same time the use of a hospital waste is implemented as construction material, bringing with it positive environmental and social benefits as far as its final disposition.eng
dc.format.mimetypeapplication/pdfspa
dc.language.isoengspa
dc.publisherJournal of Physics: Conference Seriesspa
dc.relation.ispartofJournal of Physics: Conference Series
dc.rightsContent from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI. Published under licence by IOP Publishing Ltdeng
dc.sourcehttps://iopscience.iop.org/article/10.1088/1742-6596/1329/1/012010/metaspa
dc.titleSubgrade improvement by the replacement of conventional stone aggregate by biosanitary waste treatedeng
dc.typeArtículo de revistaspa
dcterms.referencesTorres Sanchez D A, Mora Basto R L, Chaparro García A L and Sánchez Molina J 2019 Dyna 86 209spa
dcterms.referencesHurtado-Figueroa O, Cardenas-Gutierrez J A and Prada-Botia G 2018 J. Phys. Conf. Ser. 1126 012037spa
dcterms.referencesRolón Ortiz H A, Acevedo Peñaloza C and Villamizar González Y 2018 Respuestas 23 14spa
dcterms.referencesWijayasundara M, Mendis P and Crawford R H 2018 J. Clean. Prod. 174 591spa
dcterms.referencesAcevedo C H, Valencia G E and Cardenas Y D 2018 J. Phys. Conf. Ser. 1126 012033spa
dcterms.referencesCastro-Maldonado J J, PatinÕ-Murillo J A, Florian-Villa A E and Guadrón-Guerrero O E 2018 J. Phys. Conf. Ser. 1126 012022spa
dcterms.referencesHurtado-Figueroa O, Cardenas-Gutierrez J A and Gallardo O 2018 J. Phys. Conf. Ser. 1126 012040spa
dcterms.referencesHurtado-Figueroa O, Rojas-Suarez JP and Cardenas-Gutierrez J 2018 Contemporary Engineering Science 11 4957spa
dcterms.referencesUzcátegui-Gutiérrez J Y, Varela-Cárdenas A and Díaz-García J I 2016 Respuestas 21 77spa
dcterms.referencesSarabia-Guarin A, Sánchez-Molina J and Leyva-Díaz J C 2017 Respuestas 22 6spa
dcterms.referencesYaprak H, Memis S and Kaplan G 2017 J. Scien. Engi. Res 4 228spa
dcterms.referencesLuo J, Chen S, Li Q, Liu C, Gao S, Zhang J and Guo J 2019 Nanomaterials 9 325spa
dcterms.referencesVerian K P, Ashraf W and Cao Y 2018 Resour. Conserv. Recycl. 133 30spa
dcterms.referencesHurtado-Figueroa O, Cardenas-Gutierrez J A and Rojas-Suarez J P 2018 J. Phys. Conf. Ser. 1126 012041spa
dcterms.referencesMorris-Molina LH, Bamentos-Monsalve EJ, Salazar-de-Morris OJ and Ríos PM 2019 Mundo Fesc 9 17spa
dcterms.referencesMüller H S, Moffatt J S, Haist M and Vogel M 2019 IOP Conf Ser.: Earth Environ. Sci. 290 012002spa
dcterms.referencesArenales-Gáfaro P, Fernandez-Bareño Y C and Bamentos-Monsalve E J 2017 Convicciones 8 72spa
dcterms.referencesHurtado-Figueroa O, Rojas-Suarez JP and Cardenas-Gutierrez J A 2018 Contemporary Engineering Science 11 4985spa
dcterms.referencesInstituto Nacional de Vias (INVIAS) 2013 Regualcion tecnica para la construction de vias (Colombia: Instituto Nacional de Vias)spa
dcterms.referencesInstituto Nacional de Vias (INVIAS) 2013 Método para determinar la humedad de los suelos usando el horno microondas, INV-E-135 (Colombia: Instituto Nacional de Vias)spa
dcterms.referencesInstituto Nacional de Vias (INVIAS) 2013 Límite plástico e índice de plasticidad de los suelos, INV-E-126 (Colombia: Instituto Nacional de Vias)spa
dcterms.referencesInstituto Nacional de Vias (INVIAS) 2013 Determination del limite liquido de los suelos, INV-E-125 (Colombia: Instituto Nacional de Vias)spa
dcterms.referencesInstituto Nacional de Vias (INVIAS) 2013 Análisis granulométrico de agregados gruesos y finos, INV-E-213 (Colombia: Instituto Nacional de Vias)spa
dcterms.referencesInstituto Nacional de Vias (INVIAS) 2013 Densidad o masa unitaria del suelo en el terreno método del cono de arena, INV-E-161 (Colombia: Instituto Nacional de Vias)spa
dcterms.referencesInstituto Nacional de Vias (INVIAS) 2013 Relaciones humedad – peso unitario seco en los suelos (ensayo modificado de compactación), INV-E-142 (Colombia: Instituto Nacional de Vias)spa
dc.identifier.doi10.1088/1742-6596/1329/1/012010
dc.publisher.placeLondres, Inglaterraspa
dc.relation.citationeditionVol.1329 No.1.(2019)spa
dc.relation.citationendpage7spa
dc.relation.citationissue1 (2019)spa
dc.relation.citationstartpage1spa
dc.relation.citationvolume1329spa
dc.relation.citesHurtado-Figueroa, O., Suárez, J. R., & Cárdenas-Gutiérrez, J. A. (2019, September). Subgrade improvement by the replacement of conventional stone aggregate by biosanitary waste treated. In Journal of Physics: Conference Series (Vol. 1329, No. 1, p. 012010). IOP Publishing.
dc.relation.ispartofjournalJournal of Physics: Conference Seriesspa
dc.rights.accessrightsinfo:eu-repo/semantics/openAccessspa
dc.rights.creativecommonsAtribución 4.0 Internacional (CC BY 4.0)spa
dc.type.coarhttp://purl.org/coar/resource_type/c_6501spa
dc.type.contentTextspa
dc.type.driverinfo:eu-repo/semantics/articlespa
dc.type.redcolhttp://purl.org/redcol/resource_type/ARTspa
oaire.accessrightshttp://purl.org/coar/access_right/c_abf2spa
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85spa
dc.type.versioninfo:eu-repo/semantics/publishedVersionspa


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem