dc.description.abstract | Estimating the amount of flow carried by the sanitary sewer system in a locality is essential for the design of new facilities. Having a record of the flow rates allows the adequate hydraulic design of a drainage system. The objective of this work is to determine the physical parameters for the estimation of the return coefficient that allows estimating the flow rates for the sanitary sewer of the La Chivera watershed, San José de Cúcuta, Colombia. In this sense, dry weather monitoring of the wastewater in the study area was carried out. The data collected in the field were used to construct the hourly flow variation curve or inflow hydrograph in the drainage system. The average hourly flow parameters were estimated with a value of 205.7 m3/h, a value recorded at the 11th hour of the day. Similarly, the average daily flow was determined with a value of 180.3 m3/h, while the maximum peak factor was 1.14. Finally, through the physical parameters of the sanitary sewer, the return coefficient was determined, which is 0.72, a value that represents the conditions of the study area. | eng |
dc.format.extent | 8 Páginas | spa |
dc.format.mimetype | application/pdf | spa |
dc.language.iso | eng | spa |
dc.publisher | Journal of Physics: Conference Series | spa |
dc.relation.ispartof | Journal of Physics: Conference Series 2073 (2021) 012018doi:10.1088/1742-6596/2073/1/012018 | |
dc.rights | Content from this work may be used under the terms of theCreative Commons Attribution 3.0 licence. | eng |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | spa |
dc.source | https://iopscience.iop.org/article/10.1088/1742-6596/2073/1/012018/meta | spa |
dc.title | Physical parameters for the estimation of the return coefficient in the sewer of the La Chivera watershed | eng |
dc.type | Artículo de revista | spa |
dcterms.references | Bonilla-Granados C, Becerra-Triviño J, Cifuentes-Ospina G 2019 A systematic review of wastewater monitoring and its applications in urban drainage systems Respuestas 24(3) 54 | spa |
dcterms.references | Hrudka J, Csicsaiova R, Marko I, Stanko S, Skultetyova I 2020 The impact of intense rainfall on a storm sewage system of the east part of Trnava city IOP Conf. Ser.: Earth Environ. Sci. 444 012022 | spa |
dcterms.references | Marko I, Csicsaiova R, Stanko S, Skultetyova I, Hrudka J 2020 Analysis of the recent state of sewage network in Serbia IOP Conf. Ser.: Earth Environ. Sci. 444 012038 | spa |
dcterms.references | Ministerio de Vivienda, Ciudad y Territorio 2017 Reglamento Técnico para el Sector de Agua Potable y Saneamiento Básico – RAS, Resolución 0330 2017 (Colombia: Ministerio de Vivienda, Ciudad y Territorio) | spa |
dcterms.references | Elvy M 2004 Development of Infiltration Factors for the Estimation of Urban Separate Wastewater Flow in the Gippsland Water Catchment (Toowoomba: University of Southern Queensland) | spa |
dcterms.references | Hopcroft F 2014 Wastewater Treatment Concepts and Practices (New York: Momentum Press) | spa |
dcterms.references | Empresas Publicas de Medellín (EPM) 2013 Normas de Diseño de Sistemas de Alcantarillado de E.P.M (Colombia: Empresas Públicas de Medellín) | spa |
dcterms.references | Balacco G, Carbonara A, Gioia A, Iacobellis V, Ferruccio A 2017 Evaluation of peak water demand factors in puglia (Southern Italy) Water 9(2) 96 | spa |
dcterms.references | Environmental Protection Agency (EPA) 1977 Process design manual: wastewater treatment facilities for sewered small communities, EPA-625/1-77-009 (United States of America: Environmental Protection Agency) | spa |
dcterms.references | Sier D, Lansey K 2005 Monitoring sewage networks for sanitary sewer overflows Civ. Eng. Environ. Syst. 22(2) 123 | spa |
dcterms.references | López-Cualla R 2003 Elementos de Diseño para Acueductos y Alcantarillados (Bogotá: Escuela Colombiana de Ingeniería) | spa |
dcterms.references | Metcalf L, Eddy H, Tchobanoglous G 1991 Wastewater Engineering: Treatment, Disposal, and Reuse (New York: McGraw-Hill) | spa |
dcterms.references | Scheaffer R, Mendenhall W, Ott R 1987 Elementos de Muestreo (México: Editorial Ibérica) | spa |
dc.identifier.doi | 10.1088/1742-6596/2073/1/012018 | |
dc.relation.citationedition | Vol.2073 No. (2021) | spa |
dc.relation.citationendpage | 8 | spa |
dc.relation.citationissue | (2021) | spa |
dc.relation.citationstartpage | 1 | spa |
dc.relation.citationvolume | 2073 | spa |
dc.relation.cites | N J Cely-Calixto et al 2021 J. Phys.: Conf. Ser. 2073 012018 | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | spa |
dc.rights.creativecommons | Atribución 4.0 Internacional (CC BY 4.0) | spa |
dc.type.coar | http://purl.org/coar/resource_type/c_6501 | spa |
dc.type.content | Text | spa |
dc.type.driver | info:eu-repo/semantics/article | spa |
dc.type.redcol | http://purl.org/redcol/resource_type/ART | spa |
oaire.accessrights | http://purl.org/coar/access_right/c_abf2 | spa |
oaire.version | http://purl.org/coar/version/c_970fb48d4fbd8a85 | spa |
dc.type.version | info:eu-repo/semantics/publishedVersion | spa |